BTHJP - NICKEL CADIUM BATTERY CELL
- MSDS: BTHJP
- Manufacturer: SAFT AMERICA INC POWER SOURCES DIV
- Product Name: NICKEL CADIUM BATTERY CELL
- National Stock Number: 6140-01-069-7376
Product Identification
Product ID:NICKEL CADIUM BATTERY CELL
MSDS Date:03/05/1991
FSC:6140
NIIN:01-069-7376
MSDS Number: BTHJP
Responsible Party
VALDOSTA, GA 31603
US
Emergency Phone: 912-247-2331800-424-9300(CHEMTREC)
Info Phone: 912-247-2331
Preparer: BETH LOS
Cage: 09052
Contractor
Telephone: 912-247-2331
Cage: 09052
Ingredients
CADMIUM (AS CD);(SARA III)
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: SEE #3%
OSHA PEL 0.2 MG/M3 DUST; Z-2
ACGIH TLV: 0.01 MG/M3 DUST;9394
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CADMIUM HYDROXIDE
CAS: 21041-95-2
Fraction By Weight: SEE #3%
OSHA PEL 0.05 MG/M DUST&FUME
ACGIH TLV: 0.05 MG(CD)/M3 9293
TOTAL OF INGREDIENTS # 1 & 2.
RTECS: 9999999ZZ
Fraction By Weight: 7-13%
OSHA PEL 0.2MG/M3
ACGIH TLV: 0.05MG/M3
NICKEL (SARA III)
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: SEE #6%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9394
NICKEL HYDROXIDE (SARA III)
CAS: 12054-48-7
RTECS: QR7040000
Fraction By Weight: SEE #6%
OSHA PEL 1 MG(NI)/M3
ACGIH TLV: 0.1 MG(NI)/M3; 9394
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
TOTAL OF INGREDIENTS #4 & 5.
RTECS: 9999999ZZ
Fraction By Weight: 23-30%
OSHA PEL 1.0MG/M3
ACGIH TLV: 1.0MG/M3
COBALT HYDROXIDE
CAS: 21041-93-0
Fraction By Weight: 0.5%
POTASSIUM HYDROXIDE (SARA III)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 4%
OSHA PEL C, 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9394
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NOT APPLICABLE.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:UNDER NORMAL CONDITIONS OF USE, NO
EXPOSURE TO HAZARDOUS COMPONENTS EXISTS. IF INCINERATED, INHALATION
OF FUME MAY CAUSE RESPIRATORY SYSTEM IRRITATION TO PULMONARY EDEMA.
CHRONIC EXPOSUSRE MAY CAUSE K IDNEY DYSFUNCTION AND LUNG INJURY. IF
CASE IS BROKEN OPEN ELECTROLYTE IS CORROSIVE ON CONTACT.
Explanation of Carcinogenicity:PER MFG'S MSDS NOT ESTABLISHED FOR
BATTERIES; HOWEVER NI & CD ARE LISTED AS POTENTIAL CARCINOGENS BY
NTP, IARC, OSHA.
Effects of Overexposure:IF INCINERATED CHEST PAIN, COUGHING, SWEATING
CHILLS, SHORTNESS OF BREATH AND WEAKNESS.
Medical Cond Aggravated by Exposure:IF INCINERATED RESPIRATORY SYSTEM
DISORDERS, PROSTATE DISORDERS, LIVER AND KIDNEY DISORDERS.
First Aid
First Aid:IF CONTACT W/POTASSIUM OR SODIUM HYDROXIDE ELECTROLYTE, FLUSH
W/WATER FOR 15MINS AND CONTACT PHYSICIAN. IF INHALED REMOVE FROM
EXPOSURE AND CONTACT PHYSICIAN.
Fire Fighting
Extinguishing Media:MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH-APPROVED SELF-CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE CLOTHING IF INVOLVED IN FIRE.
Unusual Fire/Explosion Hazard:TOXIC METAL OXIDE FUMES MAY BE EVOLVED
DURING BURNING.
Accidental Release
Spill Release Procedures:UNDER NORMAL CONDITIONS OF USE, HAZARDOUS
COMPONENTS WILL NOT BE RELEASED. IF POTASSIUM (OR SODIUM) HYDROXIDE
ELECTROLYTE IS SPILLED, NEUTRALIZE WITH MILD ACID THEN FLUSH WITH
WATER.
Neutralizing Agent:IF POTASSIUM (OR SODIUM) HYDROXIDE ELECTROLYTE IS
SPILLED NEUTRALIZE W/MILD ACID
Handling
Handling and Storage Precautions:DO NOT BREAK OPEN BATTERY CASE. DO NOT
MUTILATE OR SHORT CIRCUIT CASE. DO NOT INCINERATE.
Other Precautions:AVOID CONTACT WITH INNER COMPONENTS.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA SELF-CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE CLOTHING TO PROTECT AGAINST FUMES IF
BATTERY INVOLVED IN A FIRE.
Ventilation:NOT APPLICABLE.
Protective Gloves:IMPERVIOUS GLOVES IF CASE PUNCTURED.
Eye Protection:SAFETY GOGGLES IF CASE PUNCTURED.
Other Protective Equipment:UNDER NORMAL CONDITIONS NO PROTECTIVE
EQUIPMENT REQUIRED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PER CTDF SAFT PN:019624-000 TYP VP130KHB WHICH IS NOT ON MSDS. MSDS
SUBMITTED BY DDMT, MEMPHIS FOR DLA430-93-C-5277.
Chemical Properties
HCC:B1
Appearance and Odor:PRISMATIC NYLON CASE WHICH COMPLETELY SEALS ABOVE
NOTED COMPONENTS WITHIN.
Stability
Stability Indicator/Materials to Avoid:YES
PER MMFG'S MSDS GENERAL STORAGE PROCEDURES FOR HAZARDOUS MATERIALS ARE
ACCEPTABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER; HOWEVER
AVOID HIGH TEMPERATURE AND RUPTURING OF BATTERY.
Hazardous Decomposition Products:METAL OXIDE FUMES.
Disposal
Waste Disposal Methods:IF DISCRDED TREAT AS RCRA HAZARDOUS WASTER.
DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.